METAL STUD PARTITIONING
Tel 0870 803 2271
Standard Partitions
- Knauf Standard Partitions utilising C-Stud or I-Stud, may be specified with confidence for non-loadbearing partitions and use fast drywall construction techniques.
- For both commercial and domestic partitions.
- Versatile systems to meet nearly every performance requirement.
- Minimum amount of components.
High Performance Twin Frame
- Knauf Twin Frame non-loadbearing partitions provide exceptional sound reduction properties using fast drywall construction techniques.
- Mainly used in the commercial sector (e.g. cinemas, auditoria and separating walls in apartments).
- For very high sound reduction values
- For very high fire resistance values.
Roomform & Roomform Quiet
Knauf Roomform and Knauf Roomform Quiet are non-loadbearing partitions and use fast drywall construction techniques.
- Specifically designed for internal partitioning in domestic situations.
- Very fast installation
- High sound reduction values
- Good impact resistance
- Minimum amount of components
- Creates strong and robust partition.
Separating Wall
- Knauf Separating Wall is a non-loadbearing partition using fast drywall construction techniques.
- Mainly specified for either separating one dwelling from another or separating a dwelling from a communal hallway or corridor, due to its high sound performance.
- Specifically designed to separate one dwelling from another
- High sound reduction values
- High fire resistance values.
Metal Furring
- Knauf Metal Furring can be used for most masonry backgrounds depending on the condition.
- Where the background is uneven and not suitable for Knauf Direct Bonding
- Where foil backed boards are used for the lining
- Where insulation is not required within the wall lining void
- Where only small service runs are required to be accommodated within the lining void
- For a stand-off of 20 – 35mm.
Wall Liner
- Knauf Wall Liner may be specified with confidence for application to most masonry backgrounds depending on the condition.
- Where a variable stand-off clearance is required between lining and background of between 16 and 125mm.
- Where background is out of true
- Where insulation is required within the wall lining void
- Where deep service runs are required to be accommodated within the lining void.
Independent 'I' Stud
- Knauf Independent ‘I’ Stud may be used where the background is not suitable to receive other types of lining.
- Where the wall lining is required to be completely independent of an adjacent wall structure
- For measured fire resistance.
- Where insulation is required within the wall lining void.
- Where substantial service runs and ducts are required to be accommodated in the lining void.
MF Ceiling System
- The Knauf MF Ceiling System can accept some degree of loading and is the more traditional form of application.
- This system can utilise one or more layers of a wide range of boards depending on the performance required. The boards are fixed onto a lightweight metal framework of Knauf MF Ceiling Channels and Knauf MF Perimeter Channels.
- The lightweight galvanised grid is suspended by either strap hangers or angle sections fixed to the structural soffit with soffit cleats.
- The tapered edge boards can then be taped and jointed using Knauf Jointing Compounds and Accessories or alternatively a 2-5mm skim coat of Knauf MultiCover, Knauf Pro Board Finish or Knauf Universal Board Finish can be applied to achieve a more traditional plaster finish.
C-Form 1
- The Knauf C-Form 1 Ceiling System can accept some degree of loading and uses fast drywall construction techniques.
- For larger ceiling areas (50m² and over)
- For spans over 4m
- Where deeper ceiling voids (over 450mm) are required.
C-Form II
- The Knauf C-Form II Ceiling System can accept some degree of loading and uses fast drywall construction techniques.
- For smaller ceiling areas (less than 50m²)
- For spans of 4m or less
- When economy and simplicity of application are required
- Where shallow ceiling voids (less than 450mm) are required.
Framed Steelwork Encasement
- Knauf Framed Encasements are suitable for encasements of columns, beams and other structural steelwork.
- Up to two hours fire protection is achievable
- Enables the exclusive use of Knauf Fireshield throughout the building to make direct decoration quick and easy.
- Knauf Fire Moistureshield offers moisture resistant qualities with the same level of fire protection.
|